Features:
6.24 Testing time is about two seconds, only capacity or inductance measurement can cause longer period.
6.25 Software can be configured to enable series of measurements before power will be shut down.
6.26 Selectable facility to calibrate the internal port resistance of port output and the zero offset of capacity
measurement with the selftest . A external capacitor with a value between 100nF and 20µF connected to pin 1
and pin 3 is necessary to compensate the offset voltage of the analog comparator. This can reduce
measurement errors of capacitors of up to 40µF. With the same capacitor a correction voltage to the internal
reference voltage is found to adjust the gain for ADC measuring with the internal reference.
10
6.27 Display the Collector cutoff current ICE0 with currentless base (10µA units) and Collector residual current
ICES with base hold to emitter level . This values are only shown, if they are not zero (especially for
Germanium transistors).
6.28 Thyristors and Triacs can only be detected, if the test current is above the holding current. Some Thyristors
and Triacs need as higher gate trigger current, than this Tester can deliver. The available testing current is only
about 6mA!
Attention: Allways be shure to discharge capacitors before connecting them to the Tester! The Tester may be
damaged before you have switched it on. There is only a little protection at the ATmega ports.
Extra causion is required if you try to test components mounted in a circuit. In either case the equipment should be
disconnected from power source and you should be shure, that no residual voltage remains in the equipment.
Specifications:
<... whiteSize: 150*80*35MM
Package includes:
1 x meter